Schema
GWMET_2022.xsd
element GWMET
complexType GWExemptions
element GWExemptions/gwExemption44Impact
element GWExemptions/gwExemption44Driver
element GWExemptions/gwExemption45Impact
element GWExemptions/gwExemption45Driver
element GWExemptions/gwDisproportionateCost
element GWExemptions/gwDisproportionateCostScale
element GWExemptions/gwDisproportionateCostAnalysis
element GWExemptions/gwDisproportionateCostAlternativeFinancing
element GWExemptions/gwDisproportionateCostOtherEULegislation
element GWExemptions/gwTechnicalInfeasibility
element GWExemptions/gwNaturalConditions
element GWExemptions/gwExemption46
element GWExemptions/gwExemption47
element GWExemptions/gwExemptionsTransboundary
element GWExemptions/gwExemptionsReference
element GWExemptions/driversGWExemptionsReference
complexType GWMET
element GWMET/countryCode
element GWMET/euRBDCode
element GWMET/dcMetadata
element GWMET/GWMethodologies
element GWMET/ThresholdValue
element GWMET/GWPressures
element GWMET/GWExemptions
complexType GWMethodologies
element GWMethodologies/gwCharacterisationReference
element GWMethodologies/diminutionDamage
element GWMethodologies/methodCriterionExtentExceedance
element GWMethodologies/proportionExceedanceAllowed
element GWMethodologies/impactsGWAbstractionBalance
element GWMethodologies/impactsGWAbstractionSWObjective
element GWMethodologies/impactsGWAbstractionSWDiminutionStatus
element GWMethodologies/impactsGWAbstractionDamageGWDE
element GWMethodologies/impactsGWAbstractionSalineIntrusion
element GWMethodologies/availableGroundwaterResource
element GWMethodologies/needsTerrestrialEcosystems
element GWMethodologies/balanceRechargeAbstraction
element GWMethodologies/trendAssessmentPerformed
element GWMethodologies/trendAssessmentMethodology
element GWMethodologies/timeSeries
element GWMethodologies/statisticalElements
element GWMethodologies/additionalTrendAssessment
element GWMethodologies/trendReversalMethodology
element GWMethodologies/thresholdValueElementProtectionEcosystem
element GWMethodologies/thresholdValueElementProtectionGWDE
element GWMethodologies/thresholdValueElementProtectionUses
element GWMethodologies/thresholdValueElementSalineIntrusion
element GWMethodologies/thresholdValuesBackgroundLevels
element GWMethodologies/transboundaryGWBPresent
element GWMethodologies/transboundaryThresholdValues
element GWMethodologies/gwMethodologiesChemicalClassificationReference
element GWMethodologies/gwMethodologiesQuantitativeClassificationReference
element GWMethodologies/gwMethodologiesTransboundaryReference
complexType GWPressures
element GWPressures/gwPressuresNotAssessed
element GWPressures/gwSignificantPressurePointSourceTools
element GWPressures/gwSignificantPressureDiffuseSourceTools
element GWPressures/gwSignificantPressureWaterAbstractionTools
element GWPressures/gwSignificantPressureArtificialRecharge
element GWPressures/gwSignificantPressureOtherSourceTools
element GWPressures/gwSignificanceDefinition
element GWPressures/gwSignificanceLinkFailure
element GWPressures/gwPressuresReference
complexType ThresholdValue
element ThresholdValue/pollutantIndicatorCode
element ThresholdValue/pollutantIndicatorCodeOther
element ThresholdValue/thresholdValueRange
element ThresholdValue/thresholdValueUnit
element ThresholdValue/thresholdDerivedFromCV
element ThresholdValue/cvDrinkingWaterValueRange
element ThresholdValue/cvDrinkingWaterValueUnit
element ThresholdValue/cvIrrigationValueRange
element ThresholdValue/cvIrrigationValueUnit
element ThresholdValue/cvIndustryValueRange
element ThresholdValue/cvIndustryValueUnit
element ThresholdValue/cvOtherDescription
element ThresholdValue/cvOtherValueRange
element ThresholdValue/cvOtherValueUnit
element ThresholdValue/thresholdValueScale
element ThresholdValue/startingPointTrendReversal
simpleType FeatureUniqueEUCodeType
simpleType NonNegativeDecimalType
simpleType PositiveDecimalType
simpleType String1000Type
simpleType String100Type
simpleType String10Type
simpleType String20Type
simpleType String2500Type
simpleType String250Type
simpleType String254Type
simpleType String25Type
simpleType String4000Type
simpleType String50Type
simpleType URLType
simpleType WiseDate
simpleType WiseDateTime
simpleType WiseDateTimeType
simpleType WiseLanguageCode_Enum
simpleType WiseYear
simpleType WiseYearMonth
XML Schema documentation generated by XMLSpy Schema Editor http://www.altova.com/xmlspy
schema location: | GWMET_2022.xsd |
attribute form default: | |
element form default: | qualified |
targetNamespace: | http://dd.eionet.europa.eu/schemas/WFD2022 |
Elements | Complex types |
GWMET | GWExemptions |
GWMET | |
GWMethodologies | |
GWPressures | |
ThresholdValue |
schema location: | http://dd.eionet.europa.eu/schemas/WFD2022/WFDCommon_2022.xsd |
attribute form default: | |
element form default: | |
targetNamespace: | http://dd.eionet.europa.eu/schemas/WFD2022/wfdcommon |
element GWMET
diagram | |||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||
type | GWMET | ||
properties |
|
||
children | countryCode euRBDCode dcMetadata GWMethodologies ThresholdValue GWPressures GWExemptions | ||
annotation |
|
||
source | <xs:element name="GWMET" type="GWMET"> <xs:annotation> <xs:documentation>Reporting of methodologies for groundwater bodies is done for each RBD. The RBD code is reported once for each schema.</xs:documentation> </xs:annotation> </xs:element> |
complexType GWExemptions
diagram | |||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||
children | gwExemption44Impact gwExemption44Driver gwExemption45Impact gwExemption45Driver gwDisproportionateCost gwDisproportionateCostScale gwDisproportionateCostAnalysis gwDisproportionateCostAlternativeFinancing gwDisproportionateCostOtherEULegislation gwTechnicalInfeasibility gwNaturalConditions gwExemption46 gwExemption47 gwExemptionsTransboundary gwExemptionsReference driversGWExemptionsReference | ||
used by |
|
||
source | <xs:complexType name="GWExemptions"> <xs:sequence> <xs:element name="gwExemption44Impact" type="SignificantImpactType_Enum" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>equired. Select from the enumeration list the impacts that are causing the application of exemptions under Article 4(4). More than one impact may be selected. If Article 4(4) exemptions have not been applied report ‘NOTA - Not applicable. The option 'NOSI - No significant impact' is not valid. Cross-schema check: The option ‘NOTA – Not applicable’ should be reported if and only if ‘Article 4(4)…’ has not been reported for: - any groundwater body under GWB/GroundWaterBody/gwQuantitativeExemptionType or GWB/ChemicalExemptionType/gwChemicalExemptionType; and - any protected area under GWB/GWAssociatedProtectedArea/protectedAreaExemption Quality checks: Element check: The option 'NOSI - No significant impact' is not valid.</xs:documentation> </xs:annotation> </xs:element> <xs:element name="gwExemption44Driver" type="Driver_Enum" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>Required. Select from the enumeration list the drivers that are causing the application of exemptions under Article 4(4). More than one driver may be selected. If Article 4(4) exemption has not been applied report ‘Exemption not applied’. Quality checks: Within-schema check: ‘Exemption not applied’ should be reported if and only if gwExemption44Impact is ‘NOTA – Not applicable’.</xs:documentation> </xs:annotation> </xs:element> <xs:element name="gwExemption45Impact" type="SignificantImpactType_Enum" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>Required. Select from the enumeration list the impacts that are causing the application of exemptions under Article 4(5). More than one impact may be selected. If Article 4(5) exemptions have not been applied report ‘NOTA - Not applicable’. The option 'NOSI - No significant impact' is not valid. Quality checks: Element check: The option ‘NOSI - No significant impact’ is not valid. Cross-schema check: The option ‘NOTA – Not applicable’ should be reported if and only if ‘Article 4(5)…’ has not been reported for: - any groundwater body under GWB/GroundWaterBody/gwQuantitativeExemptionType or GWB/ChemicalExemptionType/gwChemicalExemptionType; and any protected area under GWB/GWAssociatedProtectedArea/protectedAreaExemption</xs:documentation> </xs:annotation> </xs:element> <xs:element name="gwExemption45Driver" type="Driver_Enum" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>Required. Select the drivers from the enumeration list that are causing the application of exemptions under Article 4(5). More than one driver may be selected. If Article 4(5) exemptions have not been applied report ‘Exemption not applied’. Quality checks: Within-schema check: ‘Exemption not applied’ should be reported if and only if gwExemption45Impact is ‘NOTA – Not applicable’.</xs:documentation> </xs:annotation> </xs:element> <xs:element name="gwDisproportionateCost" type="YesNoCode_Enum"> <xs:annotation> <xs:documentation>Required. Indicate if disproportionate costs have been reported as a reason for applying exemptions under Article 4(4) or 4(5) for groundwater bodies. </xs:documentation> </xs:annotation> </xs:element> <xs:element name="gwDisproportionateCostScale" type="GeographicalScale_Enum" minOccurs="0" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>Conditional. Select from the enumeration list the scale(s) at which the calculation of costs was carried out in order to assess disproportionality. Quality checks: Conditional check: report if and only if gwDisproportionateCost is ‘Yes’.</xs:documentation> </xs:annotation> </xs:element> <xs:element name="gwDisproportionateCostAnalysis" type="DisproportionateCostAnalysis_Enum" minOccurs="0" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>Conditional. Select from the enumeration list the analysis tools that were used in assessing disproportionate costs. More than one analysis tool may be selected. Quality checks: Conditional check: report if and only if gwDisproportionateCost is ‘Yes’</xs:documentation> </xs:annotation> </xs:element> <xs:element name="gwDisproportionateCostAlternativeFinancing" type="DisproportionateCostAlternativeFinancing_Enum" minOccurs="0" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>Conditional. Select from the enumeration list the alternative financing options that have been considered to overcome the costs being disproportionate. More than one financing option may be selected. Quality checks: Conditional check: report if and only if gwDisproportionateCost is ‘Yes’.</xs:documentation> </xs:annotation> </xs:element> <xs:element name="gwDisproportionateCostOtherEULegislation" type="YesNoCode_Enum" minOccurs="0"> <xs:annotation> <xs:documentation>Conditional. Indicate whether the costs of basic measures listed in Article 11(3)(a) of the WFD have been explicitly excluded from the assessment of disproportionate costs. Quality checks: Conditional check: report if and only if gwDisproportionateCost is ‘Yes’.</xs:documentation> </xs:annotation> </xs:element> <xs:element name="gwTechnicalInfeasibility" type="TechnicalInfeasibility_Enum" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>Required. Report how ‘technical infeasibility’ has been interpreted in the context of application of exemptions for groundwater bodies. More than one option may be selected. Quality checks: Within-schema check: the option ‘Technical infeasibility has not been used as a reason for exemption’ is not compatible with any other.</xs:documentation> </xs:annotation> </xs:element> <xs:element name="gwNaturalConditions" type="GWNaturalConditions_Enum" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>Required. Select from the enumeration list the elements considered when determining that natural conditions require an exemption under Article 4(4). Quality checks: Within-schema check: the option ‘Natural condition has not been used as a reason for exemption for groundwater bodies’ is not compatible with any other.</xs:documentation> </xs:annotation> </xs:element> <xs:element name="gwExemption46" type="Exemption46_Enum" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>Required. Select from the enumeration list the reasons that have led to the application of exemptions under Article 4(6). More than one reason may be selected. Quality checks: Within-schema check: the option ‘Article 4(6) has not been applied’ is not compatible with any other. Cross-schema check: The option ‘Article 4(6) has not been applied’ should be reported if and only if ‘Article 4(6)…’ has not been reported for: - any groundwater body under GWB/GroundWaterBody/gwQuantitativeExemptionType or GWB/ChemicalExemptionType/gwChemicalExemptionType; and any protected area under GWB/GWAssociatedProtectedArea/protectedAreaExemption</xs:documentation> </xs:annotation> </xs:element> <xs:element name="gwExemption47" type="Exemption47_Enum" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>Required. Select from the enumeration list the modifications that have led to the application of exemptions under Article 4(7). More than one modification may be selected. Quality checks: Within-schema check: the option ‘Article 4(7) has not been applied’ is not compatible with any other. Cross-schema check: The option ‘Article 4(7) has not been applied’ should be reported if and only if ‘Article 4(7)…’ has not been reported for: - any groundwater body under GWB/GroundWaterBody/gwQuantitativeExemptionType or GWB/ChemicalExemptionType/gwChemicalExemptionType; and any protected area under GWB/GWAssociatedProtectedArea/protectedAreaExemption</xs:documentation> </xs:annotation> </xs:element> <xs:element name="gwExemptionsTransboundary" type="YesNoNotApplicable_Enum"> <xs:annotation> <xs:documentation>Required. Indicate whether the application of exemptions for groundwater has been co-ordinated in a transboundary context. Report ‘Not applicable’ if the RBD is not international. Quality checks: Cross-schema check: Report ‘Not applicable’ if and only if RBDSUCA/RBD/internationalRBD is ‘No’.</xs:documentation> </xs:annotation> </xs:element> <xs:element name="gwExemptionsReference" type="ReferenceType" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>Required. Provide references or hyperlinks to the relevant documents and sections where specific information on the application of exemptions for groundwater bodies can be found. Guidance on what should be included in this document is provided in Section 8.5.3.2.</xs:documentation> </xs:annotation> </xs:element> <xs:element name="driversGWExemptionsReference" type="ReferenceType" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>Required. Provide references or hyperlinks to the relevant documents and sections where information on the drivers behind exemptions for groundwater bodies can be found. Guidance on what should be included in this document is provided in Section 8.5.3.2.</xs:documentation> </xs:annotation> </xs:element> </xs:sequence> </xs:complexType> |
element GWExemptions/gwExemption44Impact
diagram | |||||||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||||||
type | SignificantImpactType_Enum | ||||||
properties |
|
||||||
annotation |
|
||||||
source | <xs:element name="gwExemption44Impact" type="SignificantImpactType_Enum" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>equired. Select from the enumeration list the impacts that are causing the application of exemptions under Article 4(4). More than one impact may be selected. If Article 4(4) exemptions have not been applied report ‘NOTA - Not applicable. The option 'NOSI - No significant impact' is not valid. Cross-schema check: The option ‘NOTA – Not applicable’ should be reported if and only if ‘Article 4(4)…’ has not been reported for: - any groundwater body under GWB/GroundWaterBody/gwQuantitativeExemptionType or GWB/ChemicalExemptionType/gwChemicalExemptionType; and - any protected area under GWB/GWAssociatedProtectedArea/protectedAreaExemption Quality checks: Element check: The option 'NOSI - No significant impact' is not valid.</xs:documentation> </xs:annotation> </xs:element> |
element GWExemptions/gwExemption44Driver
diagram | |||||||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||||||
type | Driver_Enum | ||||||
properties |
|
||||||
annotation |
|
||||||
source | <xs:element name="gwExemption44Driver" type="Driver_Enum" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>Required. Select from the enumeration list the drivers that are causing the application of exemptions under Article 4(4). More than one driver may be selected. If Article 4(4) exemption has not been applied report ‘Exemption not applied’. Quality checks: Within-schema check: ‘Exemption not applied’ should be reported if and only if gwExemption44Impact is ‘NOTA – Not applicable’.</xs:documentation> </xs:annotation> </xs:element> |
element GWExemptions/gwExemption45Impact
diagram | |||||||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||||||
type | SignificantImpactType_Enum | ||||||
properties |
|
||||||
annotation |
|
||||||
source | <xs:element name="gwExemption45Impact" type="SignificantImpactType_Enum" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>Required. Select from the enumeration list the impacts that are causing the application of exemptions under Article 4(5). More than one impact may be selected. If Article 4(5) exemptions have not been applied report ‘NOTA - Not applicable’. The option 'NOSI - No significant impact' is not valid. Quality checks: Element check: The option ‘NOSI - No significant impact’ is not valid. Cross-schema check: The option ‘NOTA – Not applicable’ should be reported if and only if ‘Article 4(5)…’ has not been reported for: - any groundwater body under GWB/GroundWaterBody/gwQuantitativeExemptionType or GWB/ChemicalExemptionType/gwChemicalExemptionType; and any protected area under GWB/GWAssociatedProtectedArea/protectedAreaExemption</xs:documentation> </xs:annotation> </xs:element> |
element GWExemptions/gwExemption45Driver
diagram | |||||||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||||||
type | Driver_Enum | ||||||
properties |
|
||||||
annotation |
|
||||||
source | <xs:element name="gwExemption45Driver" type="Driver_Enum" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>Required. Select the drivers from the enumeration list that are causing the application of exemptions under Article 4(5). More than one driver may be selected. If Article 4(5) exemptions have not been applied report ‘Exemption not applied’. Quality checks: Within-schema check: ‘Exemption not applied’ should be reported if and only if gwExemption45Impact is ‘NOTA – Not applicable’.</xs:documentation> </xs:annotation> </xs:element> |
element GWExemptions/gwDisproportionateCost
diagram | |||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||
type | YesNoCode_Enum | ||
properties |
|
||
annotation |
|
||
source | <xs:element name="gwDisproportionateCost" type="YesNoCode_Enum"> <xs:annotation> <xs:documentation>Required. Indicate if disproportionate costs have been reported as a reason for applying exemptions under Article 4(4) or 4(5) for groundwater bodies. </xs:documentation> </xs:annotation> </xs:element> |
element GWExemptions/gwDisproportionateCostScale
diagram | |||||||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||||||
type | GeographicalScale_Enum | ||||||
properties |
|
||||||
annotation |
|
||||||
source | <xs:element name="gwDisproportionateCostScale" type="GeographicalScale_Enum" minOccurs="0" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>Conditional. Select from the enumeration list the scale(s) at which the calculation of costs was carried out in order to assess disproportionality. Quality checks: Conditional check: report if and only if gwDisproportionateCost is ‘Yes’.</xs:documentation> </xs:annotation> </xs:element> |
element GWExemptions/gwDisproportionateCostAnalysis
diagram | |||||||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||||||
type | DisproportionateCostAnalysis_Enum | ||||||
properties |
|
||||||
annotation |
|
||||||
source | <xs:element name="gwDisproportionateCostAnalysis" type="DisproportionateCostAnalysis_Enum" minOccurs="0" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>Conditional. Select from the enumeration list the analysis tools that were used in assessing disproportionate costs. More than one analysis tool may be selected. Quality checks: Conditional check: report if and only if gwDisproportionateCost is ‘Yes’</xs:documentation> </xs:annotation> </xs:element> |
element GWExemptions/gwDisproportionateCostAlternativeFinancing
diagram | |||||||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||||||
type | DisproportionateCostAlternativeFinancing_Enum | ||||||
properties |
|
||||||
annotation |
|
||||||
source | <xs:element name="gwDisproportionateCostAlternativeFinancing" type="DisproportionateCostAlternativeFinancing_Enum" minOccurs="0" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>Conditional. Select from the enumeration list the alternative financing options that have been considered to overcome the costs being disproportionate. More than one financing option may be selected. Quality checks: Conditional check: report if and only if gwDisproportionateCost is ‘Yes’.</xs:documentation> </xs:annotation> </xs:element> |
element GWExemptions/gwDisproportionateCostOtherEULegislation
diagram | |||||||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||||||
type | YesNoCode_Enum | ||||||
properties |
|
||||||
annotation |
|
||||||
source | <xs:element name="gwDisproportionateCostOtherEULegislation" type="YesNoCode_Enum" minOccurs="0"> <xs:annotation> <xs:documentation>Conditional. Indicate whether the costs of basic measures listed in Article 11(3)(a) of the WFD have been explicitly excluded from the assessment of disproportionate costs. Quality checks: Conditional check: report if and only if gwDisproportionateCost is ‘Yes’.</xs:documentation> </xs:annotation> </xs:element> |
element GWExemptions/gwTechnicalInfeasibility
diagram | |||||||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||||||
type | TechnicalInfeasibility_Enum | ||||||
properties |
|
||||||
annotation |
|
||||||
source | <xs:element name="gwTechnicalInfeasibility" type="TechnicalInfeasibility_Enum" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>Required. Report how ‘technical infeasibility’ has been interpreted in the context of application of exemptions for groundwater bodies. More than one option may be selected. Quality checks: Within-schema check: the option ‘Technical infeasibility has not been used as a reason for exemption’ is not compatible with any other.</xs:documentation> </xs:annotation> </xs:element> |
element GWExemptions/gwNaturalConditions
diagram | |||||||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||||||
type | GWNaturalConditions_Enum | ||||||
properties |
|
||||||
annotation |
|
||||||
source | <xs:element name="gwNaturalConditions" type="GWNaturalConditions_Enum" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>Required. Select from the enumeration list the elements considered when determining that natural conditions require an exemption under Article 4(4). Quality checks: Within-schema check: the option ‘Natural condition has not been used as a reason for exemption for groundwater bodies’ is not compatible with any other.</xs:documentation> </xs:annotation> </xs:element> |
element GWExemptions/gwExemption46
diagram | |||||||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||||||
type | Exemption46_Enum | ||||||
properties |
|
||||||
annotation |
|
||||||
source | <xs:element name="gwExemption46" type="Exemption46_Enum" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>Required. Select from the enumeration list the reasons that have led to the application of exemptions under Article 4(6). More than one reason may be selected. Quality checks: Within-schema check: the option ‘Article 4(6) has not been applied’ is not compatible with any other. Cross-schema check: The option ‘Article 4(6) has not been applied’ should be reported if and only if ‘Article 4(6)…’ has not been reported for: - any groundwater body under GWB/GroundWaterBody/gwQuantitativeExemptionType or GWB/ChemicalExemptionType/gwChemicalExemptionType; and any protected area under GWB/GWAssociatedProtectedArea/protectedAreaExemption</xs:documentation> </xs:annotation> </xs:element> |
element GWExemptions/gwExemption47
diagram | |||||||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||||||
type | Exemption47_Enum | ||||||
properties |
|
||||||
annotation |
|
||||||
source | <xs:element name="gwExemption47" type="Exemption47_Enum" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>Required. Select from the enumeration list the modifications that have led to the application of exemptions under Article 4(7). More than one modification may be selected. Quality checks: Within-schema check: the option ‘Article 4(7) has not been applied’ is not compatible with any other. Cross-schema check: The option ‘Article 4(7) has not been applied’ should be reported if and only if ‘Article 4(7)…’ has not been reported for: - any groundwater body under GWB/GroundWaterBody/gwQuantitativeExemptionType or GWB/ChemicalExemptionType/gwChemicalExemptionType; and any protected area under GWB/GWAssociatedProtectedArea/protectedAreaExemption</xs:documentation> </xs:annotation> </xs:element> |
element GWExemptions/gwExemptionsTransboundary
diagram | |||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||
type | YesNoNotApplicable_Enum | ||
properties |
|
||
annotation |
|
||
source | <xs:element name="gwExemptionsTransboundary" type="YesNoNotApplicable_Enum"> <xs:annotation> <xs:documentation>Required. Indicate whether the application of exemptions for groundwater has been co-ordinated in a transboundary context. Report ‘Not applicable’ if the RBD is not international. Quality checks: Cross-schema check: Report ‘Not applicable’ if and only if RBDSUCA/RBD/internationalRBD is ‘No’.</xs:documentation> </xs:annotation> </xs:element> |
element GWExemptions/gwExemptionsReference
diagram | |||||||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||||||
type | ReferenceType | ||||||
properties |
|
||||||
annotation |
|
||||||
source | <xs:element name="gwExemptionsReference" type="ReferenceType" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>Required. Provide references or hyperlinks to the relevant documents and sections where specific information on the application of exemptions for groundwater bodies can be found. Guidance on what should be included in this document is provided in Section 8.5.3.2.</xs:documentation> </xs:annotation> </xs:element> |
element GWExemptions/driversGWExemptionsReference
diagram | |||||||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||||||
type | ReferenceType | ||||||
properties |
|
||||||
annotation |
|
||||||
source | <xs:element name="driversGWExemptionsReference" type="ReferenceType" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>Required. Provide references or hyperlinks to the relevant documents and sections where information on the drivers behind exemptions for groundwater bodies can be found. Guidance on what should be included in this document is provided in Section 8.5.3.2.</xs:documentation> </xs:annotation> </xs:element> |
complexType GWMET
diagram | |||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||
children | countryCode euRBDCode dcMetadata GWMethodologies ThresholdValue GWPressures GWExemptions | ||
used by |
|
||
source | <xs:complexType name="GWMET"> <xs:sequence> <xs:element name="countryCode" type="CountryCode_Enum"> <xs:annotation> <xs:documentation>Two-letter ISO country code</xs:documentation> </xs:annotation> </xs:element> <xs:element name="euRBDCode" type="FeatureUniqueEUCodeType"> <xs:annotation> <xs:documentation>Required. Unique EU code of the River Basin District. Prefix the RBD’s national, unique code with the Member State’s 2-alpha character ISO country code. Quality checks: Element check: First 2 characters must be the Member State’s 2-alpha character ISO country code. Cross-schema check: The reported euRBDCode must be consistent with the codes reported in RBDSUCA/RBD/euRBDCode.</xs:documentation> </xs:annotation> </xs:element> <xs:element name="dcMetadata" type="dcMetadata"/> <xs:element name="GWMethodologies" type="GWMethodologies"> <xs:annotation> <xs:documentation>Table 8.3.3.2</xs:documentation> </xs:annotation> </xs:element> <xs:element name="ThresholdValue" type="ThresholdValue" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>Table 8.3.3.2 Latter part</xs:documentation> </xs:annotation> </xs:element> <xs:element name="GWPressures" type="GWPressures"> <xs:annotation> <xs:documentation>Table 8.4.3.2 Latter part</xs:documentation> </xs:annotation> </xs:element> <xs:element name="GWExemptions" type="GWExemptions"> <xs:annotation> <xs:documentation>Table 8.5.3.2 part</xs:documentation> </xs:annotation> </xs:element> </xs:sequence> </xs:complexType> |
element GWMET/countryCode
diagram | |||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||
type | CountryCode_Enum | ||
properties |
|
||
annotation |
|
||
source | <xs:element name="countryCode" type="CountryCode_Enum"> <xs:annotation> <xs:documentation>Two-letter ISO country code</xs:documentation> </xs:annotation> </xs:element> |
element GWMET/euRBDCode
diagram | |||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||
type | FeatureUniqueEUCodeType | ||
properties |
|
||
annotation |
|
||
source | <xs:element name="euRBDCode" type="FeatureUniqueEUCodeType"> <xs:annotation> <xs:documentation>Required. Unique EU code of the River Basin District. Prefix the RBD’s national, unique code with the Member State’s 2-alpha character ISO country code. Quality checks: Element check: First 2 characters must be the Member State’s 2-alpha character ISO country code. Cross-schema check: The reported euRBDCode must be consistent with the codes reported in RBDSUCA/RBD/euRBDCode.</xs:documentation> </xs:annotation> </xs:element> |
element GWMET/dcMetadata
diagram | |||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||
type | dcMetadata | ||
properties |
|
||
source | <xs:element name="dcMetadata" type="dcMetadata"/> |
element GWMET/GWMethodologies
element GWMET/ThresholdValue
diagram | |||||||||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||||||||
type | ThresholdValue | ||||||||
properties |
|
||||||||
children | pollutantIndicatorCode pollutantIndicatorCodeOther thresholdValueRange thresholdValueUnit thresholdDerivedFromCV cvDrinkingWaterValueRange cvDrinkingWaterValueUnit cvIrrigationValueRange cvIrrigationValueUnit cvIndustryValueRange cvIndustryValueUnit cvOtherDescription cvOtherValueRange cvOtherValueUnit thresholdValueScale startingPointTrendReversal | ||||||||
annotation |
|
||||||||
source | <xs:element name="ThresholdValue" type="ThresholdValue" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>Table 8.3.3.2 Latter part</xs:documentation> </xs:annotation> </xs:element> |
element GWMET/GWPressures
diagram | |||||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||||
type | GWPressures | ||||
properties |
|
||||
children | gwPressuresNotAssessed gwSignificantPressurePointSourceTools gwSignificantPressureDiffuseSourceTools gwSignificantPressureWaterAbstractionTools gwSignificantPressureArtificialRecharge gwSignificantPressureOtherSourceTools gwSignificanceDefinition gwSignificanceLinkFailure gwPressuresReference | ||||
annotation |
|
||||
source | <xs:element name="GWPressures" type="GWPressures"> <xs:annotation> <xs:documentation>Table 8.4.3.2 Latter part</xs:documentation> </xs:annotation> </xs:element> |
element GWMET/GWExemptions
diagram | |||||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||||
type | GWExemptions | ||||
properties |
|
||||
children | gwExemption44Impact gwExemption44Driver gwExemption45Impact gwExemption45Driver gwDisproportionateCost gwDisproportionateCostScale gwDisproportionateCostAnalysis gwDisproportionateCostAlternativeFinancing gwDisproportionateCostOtherEULegislation gwTechnicalInfeasibility gwNaturalConditions gwExemption46 gwExemption47 gwExemptionsTransboundary gwExemptionsReference driversGWExemptionsReference | ||||
annotation |
|
||||
source | <xs:element name="GWExemptions" type="GWExemptions"> <xs:annotation> <xs:documentation>Table 8.5.3.2 part</xs:documentation> </xs:annotation> </xs:element> |
complexType GWMethodologies
diagram | |||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||
children | gwCharacterisationReference diminutionDamage methodCriterionExtentExceedance proportionExceedanceAllowed impactsGWAbstractionBalance impactsGWAbstractionSWObjective impactsGWAbstractionSWDiminutionStatus impactsGWAbstractionDamageGWDE impactsGWAbstractionSalineIntrusion availableGroundwaterResource needsTerrestrialEcosystems balanceRechargeAbstraction trendAssessmentPerformed trendAssessmentMethodology timeSeries statisticalElements additionalTrendAssessment trendReversalMethodology thresholdValueElementProtectionEcosystem thresholdValueElementProtectionGWDE thresholdValueElementProtectionUses thresholdValueElementSalineIntrusion thresholdValuesBackgroundLevels transboundaryGWBPresent transboundaryThresholdValues gwMethodologiesChemicalClassificationReference gwMethodologiesQuantitativeClassificationReference gwMethodologiesTransboundaryReference | ||
used by |
|
||
annotation |
|
||
source | <xs:complexType name="GWMethodologies"> <xs:annotation> <xs:documentation>Required. Indicate whether a methodology for assessing trend reversal has been established. </xs:documentation> </xs:annotation> <xs:sequence> <xs:element name="gwCharacterisationReference" type="ReferenceType" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>Required. There are no standard methodologies for the delineation and characterisation of groundwater bodies, therefore no targeted questions have been developed. Member States should, however, provide information relating to the initial characterisation and further characterisation of groundwater bodies. See Section 8.2.3.2 for the detailed information that is required. Provide references or hyperlinks to the relevant documents where specific information can be found. </xs:documentation> </xs:annotation> </xs:element> <xs:element name="diminutionDamage" type="YesNoNotApplicable_Union_Enum"> <xs:annotation> <xs:documentation>Required. Indicate whether diminution of surface water chemical and ecological quality and damage to groundwater dependent terrestrial ecosystems due to transfer of pollutants from the groundwater body have been considered in the assessment of chemical status. Report ‘Not applicable’ if there are no groundwater dependent surface water or terrestrial ecosystems. Quality checks: Cross-schema check: ‘Not applicable’ is a valid choice only if GWB/GroundWaterBody/linkSurfaceWaterBody is ‘No’ for all groundwater bodies and GWB/GroundWaterBody/linkTerrestrialEcosystem is also ‘No’ for all groundwater bodies.</xs:documentation> </xs:annotation> </xs:element> <xs:element name="methodCriterionExtentExceedance" type="MethodCriteriumExtentExeedence_Enum"> <xs:annotation> <xs:documentation>Required. Report which method or criterion has been applied to estimate the extent of the groundwater body that exceeds groundwater quality standards or threshold values, and what extent of the groundwater body exceeding groundwater quality standard or threshold value is considered acceptable for a groundwater body to be considered in good chemical status: - Method 1: Proportion (%) of the number of monitoring sites exceeding a groundwater quality standard or threshold value compared to the total number of monitoring sites in the whole groundwater body - Method 2: Proportion (%) of the total area of the groundwater body represented by monitoring sites exceeding a groundwater quality standard or threshold value compared to the total area of the groundwater body. - Method 3: Proportion (%) of the total volume of the groundwater body represented by monitoring sites exceeding a groundwater quality standard or threshold value compared to the total volume of the groundwater body. - Other - None Not relevant, as no monitoring site exceeds any groundwater quality standard or threshold value for any pollutant</xs:documentation> </xs:annotation> </xs:element> <xs:element name="proportionExceedanceAllowed" type="NumberDecimal0100Type" minOccurs="0"> <xs:annotation> <xs:documentation>Conditional. If Method 1, Method 2 or Method 3 has been used to estimate the extent of the groundwater body that exceeds groundwater quality standards or threshold values, state the proportion (%) of monitoring sites, area or volume (as appropriate) where exceedance is considered acceptable for a groundwater body to be considered in good chemical status. Quality checks: Conditional check: Report if and only if methodCriterionExtentExceedance is ‘Method 1’, ‘Method 2’ or ‘Method 3’.</xs:documentation> </xs:annotation> </xs:element> <xs:element name="impactsGWAbstractionBalance" type="YesNoCode_Enum"> <xs:annotation> <xs:documentation>Required. Has whether the available groundwater resource is not exceeded by the long term annual average rate of abstraction been considered when assessing groundwater quantitative status? For further information regarding abstraction, refer to CIS Guidance Document No. 18 on groundwater status and trend assessment.</xs:documentation> </xs:annotation> </xs:element> <xs:element name="impactsGWAbstractionSWObjective" type="YesNoCode_Enum"> <xs:annotation> <xs:documentation>Required. Has failure to achieve the WFD Environmental Objectives for associated surface water bodies resulting from anthropogenic water level alteration or change in flow conditions been considered when assessing groundwater quantitative status? For further informationregarding abstraction, refer to CIS Guidance Document No. 18 on groundwater status and trend assessment.</xs:documentation> </xs:annotation> </xs:element> <xs:element name="impactsGWAbstractionSWDiminutionStatus" type="YesNoCode_Enum"> <xs:annotation> <xs:documentation>Required. Has significant diminution in the status of surface waters resulting from anthropogenic water level alteration or change in flow conditions been considered when assessing groundwater quantitative status? For further information regarding abstraction, refer to CIS Guidance Document No. 18 on groundwater status and trend assessment.</xs:documentation> </xs:annotation> </xs:element> <xs:element name="impactsGWAbstractionDamageGWDE" type="YesNoCode_Enum"> <xs:annotation> <xs:documentation>Required. Has significant damage to groundwater-dependent terrestrial ecosystems resulting from an anthropogenic water level alteration been considered when assessing groundwater quantitative status? For further information regarding abstraction, refer to CIS Guidance Document No. 18 on groundwater status and trend assessment.</xs:documentation> </xs:annotation> </xs:element> <xs:element name="impactsGWAbstractionSalineIntrusion" type="YesNoCode_Enum"> <xs:annotation> <xs:documentation>Required. Have regional saline or other intrusions resulting from anthropogenically induced sustained changes in flow direction been considered when assessing groundwater quantitative status? For further information regarding abstraction, refer to CIS Guidance Document No. 18 on groundwater status and trend assessment.</xs:documentation> </xs:annotation> </xs:element> <xs:element name="availableGroundwaterResource" type="YesNoPartially_Union_Enum"> <xs:annotation> <xs:documentation>Required. Indicate whether the criterion of ‘available groundwater resource’ has been applied in accordance with WFD Article 2(27), which defines ‘available groundwater resource’ as the long-term annual average rate of overall recharge of the body of groundwater less the long-term annual rate of flow required to achieve the ecological quality objectives for associated surface waters, to avoid any significant diminution in the ecological status of such waters and to avoid any significant damage to associated terrestrial ecosystems.</xs:documentation> </xs:annotation> </xs:element> <xs:element name="needsTerrestrialEcosystems" type="YesNoNotApplicable_Union_Enum"> <xs:annotation> <xs:documentation>Required. Indicate whether the needs of the terrestrial ecosystems associated to groundwater bodies have been assessed. Report ‘Not applicable’ if there are no terrestrial ecosystems associated to groundwater bodies. Quality checks: Cross-schema check: ‘Not applicable’ is a valid choice if and only if GWB/GroundWaterBody/linkTerrestrialEcosystem is ‘No’ for all groundwater bodies.</xs:documentation> </xs:annotation> </xs:element> <xs:element name="balanceRechargeAbstraction" type="BalanceRechargeAbstraction_Enum"> <xs:annotation> <xs:documentation>Required. Report the approach used to assess the balance between recharge and abstraction of groundwater. - Method 1: A comparison of annual average groundwater abstraction against ‘available groundwater resource’ was done for every groundwater body - Method 2: A comparison of annual average groundwater abstraction against ‘available groundwater resource’ was done for a subset of all groundwater bodies - Method 3: Where reliable data on groundwater levels across the groundwater body is available, it can be used to identify the presence of a sustained long-term decline in water levels caused by groundwater abstraction. Where such a decline is present it indicates that the conditions for good status are not being met and the groundwater body is considered in poor status. - Not considered For further information regarding abstraction, refer to CIS Guidance Document No. 18 on groundwater status and trend assessment.</xs:documentation> </xs:annotation> </xs:element> <xs:element name="trendAssessmentPerformed" type="YesNoCode_Enum"> <xs:annotation> <xs:documentation>Required. Indicate whether trend assessment in groundwater pollutants been performed.</xs:documentation> </xs:annotation> </xs:element> <xs:element name="trendAssessmentMethodology" type="YesNoCode_Enum" minOccurs="0"> <xs:annotation> <xs:documentation>Conditional. If trend assessment in groundwater pollutants was performed, indicate whether a methodology for identifying significant and upward trends in any pollutant’s concentration has been applied. Quality checks: Conditional check: Report if and only if trendAssessmentPerformed is ‘Yes’.</xs:documentation> </xs:annotation> </xs:element> <xs:element name="timeSeries" type="YearRangeType" minOccurs="0"> <xs:annotation> <xs:documentation>Conditional. If trend assessment in groundwater pollutants was performed, report the starting and finishing year for that assessment, in the format YYYY--YYYY. Quality checks: Conditional check: Report if and only if trendAssessmentPerformed is ‘Yes’.</xs:documentation> </xs:annotation> </xs:element> <xs:element name="statisticalElements" type="StatisticalElements_Enum" minOccurs="0"> <xs:annotation> <xs:documentation>Conditional. If trend assessment in groundwater pollutants was performed, select from the enumeration list which statistical element was used. Quality checks: Conditional check: Report if and only if trendAssessmentPerformed is ‘Yes’.</xs:documentation> </xs:annotation> </xs:element> <xs:element name="additionalTrendAssessment" type="YesNoCode_Enum"> <xs:annotation> <xs:documentation>Required. Indicate whether additional trend assessments were applied in order to assess the impacts of existing plumes of pollution (according to Article 5(5) of the GWD).</xs:documentation> </xs:annotation> </xs:element> <xs:element name="trendReversalMethodology" type="YesNoCode_Enum"> <xs:annotation> <xs:documentation>Required. Indicate whether a methodology for assessing trend reversal has been established. </xs:documentation> </xs:annotation> </xs:element> <xs:element name="thresholdValueElementProtectionEcosystem" type="YesNoCode_Enum"> <xs:annotation> <xs:documentation>Required. Has the protection of aquatic ecosystems (surface waters) been considered during the establishment of the groundwater threshold values? </xs:documentation> </xs:annotation> </xs:element> <xs:element name="thresholdValueElementProtectionGWDE" type="YesNoCode_Enum"> <xs:annotation> <xs:documentation>Required. Has the protection of groundwater dependent terrestrial ecosystems (e.g. wetlands) been considered during the establishment of the groundwater threshold values? </xs:documentation> </xs:annotation> </xs:element> <xs:element name="thresholdValueElementProtectionUses" type="YesNoCode_Enum"> <xs:annotation> <xs:documentation>Required. Have the actual and potential legitimate uses and functions of groundwater (e.g. drinking water, irrigation, industrial use) been considered during the establishment of the groundwater threshold values? </xs:documentation> </xs:annotation> </xs:element> <xs:element name="thresholdValueElementSalineIntrusion" type="YesNoCode_Enum"> <xs:annotation> <xs:documentation>Required. Have saline or other intrusions been considered during the establishment of the groundwater threshold values? </xs:documentation> </xs:annotation> </xs:element> <xs:element name="thresholdValuesBackgroundLevels" type="ThresholdValuesBackgroundLevels_Enum"> <xs:annotation> <xs:documentation>Required. Report whether background levels of naturally occurring substances have been considered during the establishment of threshold values. </xs:documentation> </xs:annotation> </xs:element> <xs:element name="transboundaryGWBPresent" type="YesNoCode_Enum"> <xs:annotation> <xs:documentation>Required. Indicate whether there are any transboundary groundwater bodies in the RBD. Quality checks: Cross-schema check: ‘No’ should be reported if and only if GWB/GroundWaterBody/groundwaterBodyTransboundary is ‘No’ for all groundwater bodies.</xs:documentation> </xs:annotation> </xs:element> <xs:element name="transboundaryThresholdValues" type="YesNoCode_Enum" minOccurs="0"> <xs:annotation> <xs:documentation>Conditional. If there are transboundary groundwater bodies, indicate whether the establishment of threshold values has been co-ordinated with the neighbouring countries concerned. Quality checks: Conditional check: Report if and only if transboundaryGWBPresent is ‘Yes’.</xs:documentation> </xs:annotation> </xs:element> <xs:element name="gwMethodologiesChemicalClassificationReference" type="ReferenceType" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>Required. Provide references or hyperlinks to the documents and sections where relevant information relating to methodologies for the classification of chemical status of groundwater, for upward trend assessment and for trend reversal can be found. Guidance on what should be included in this document is provided in Section 8.3.3.2.</xs:documentation> </xs:annotation> </xs:element> <xs:element name="gwMethodologiesQuantitativeClassificationReference" type="ReferenceType" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>Required. Provide references or hyperlinks to the documents and sections where relevant information relating to methodologies for the classification of quantitative status of groundwater can be found. Guidance on what should be included in this document is provided in Section 8.3.3.2.</xs:documentation> </xs:annotation> </xs:element> <xs:element name="gwMethodologiesTransboundaryReference" type="ReferenceType" minOccurs="0" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>Conditional. Provide references or hyperlinks to the documents and sections where relevant information relating to transboundary co-ordination of threshold value setting can be found. Guidance on what should be included in this document is provided in Section 8.3.3.2. Quality checks: report if 'transboundaryGWBPresent' is 'Yes'.</xs:documentation> </xs:annotation> </xs:element> </xs:sequence> </xs:complexType> |
element GWMethodologies/gwCharacterisationReference
diagram | |||||||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||||||
type | ReferenceType | ||||||
properties |
|
||||||
annotation |
|
||||||
source | <xs:element name="gwCharacterisationReference" type="ReferenceType" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>Required. There are no standard methodologies for the delineation and characterisation of groundwater bodies, therefore no targeted questions have been developed. Member States should, however, provide information relating to the initial characterisation and further characterisation of groundwater bodies. See Section 8.2.3.2 for the detailed information that is required. Provide references or hyperlinks to the relevant documents where specific information can be found. </xs:documentation> </xs:annotation> </xs:element> |
element GWMethodologies/diminutionDamage
diagram | |||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||
type | YesNoNotApplicable_Union_Enum | ||
properties |
|
||
annotation |
|
||
source | <xs:element name="diminutionDamage" type="YesNoNotApplicable_Union_Enum"> <xs:annotation> <xs:documentation>Required. Indicate whether diminution of surface water chemical and ecological quality and damage to groundwater dependent terrestrial ecosystems due to transfer of pollutants from the groundwater body have been considered in the assessment of chemical status. Report ‘Not applicable’ if there are no groundwater dependent surface water or terrestrial ecosystems. Quality checks: Cross-schema check: ‘Not applicable’ is a valid choice only if GWB/GroundWaterBody/linkSurfaceWaterBody is ‘No’ for all groundwater bodies and GWB/GroundWaterBody/linkTerrestrialEcosystem is also ‘No’ for all groundwater bodies.</xs:documentation> </xs:annotation> </xs:element> |
element GWMethodologies/methodCriterionExtentExceedance
diagram | |||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||
type | MethodCriteriumExtentExeedence_Enum | ||
properties |
|
||
annotation |
|
||
source | <xs:element name="methodCriterionExtentExceedance" type="MethodCriteriumExtentExeedence_Enum"> <xs:annotation> <xs:documentation>Required. Report which method or criterion has been applied to estimate the extent of the groundwater body that exceeds groundwater quality standards or threshold values, and what extent of the groundwater body exceeding groundwater quality standard or threshold value is considered acceptable for a groundwater body to be considered in good chemical status: - Method 1: Proportion (%) of the number of monitoring sites exceeding a groundwater quality standard or threshold value compared to the total number of monitoring sites in the whole groundwater body - Method 2: Proportion (%) of the total area of the groundwater body represented by monitoring sites exceeding a groundwater quality standard or threshold value compared to the total area of the groundwater body. - Method 3: Proportion (%) of the total volume of the groundwater body represented by monitoring sites exceeding a groundwater quality standard or threshold value compared to the total volume of the groundwater body. - Other - None Not relevant, as no monitoring site exceeds any groundwater quality standard or threshold value for any pollutant</xs:documentation> </xs:annotation> </xs:element> |
element GWMethodologies/proportionExceedanceAllowed
diagram | |||||||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||||||
type | NumberDecimal0100Type | ||||||
properties |
|
||||||
annotation |
|
||||||
source | <xs:element name="proportionExceedanceAllowed" type="NumberDecimal0100Type" minOccurs="0"> <xs:annotation> <xs:documentation>Conditional. If Method 1, Method 2 or Method 3 has been used to estimate the extent of the groundwater body that exceeds groundwater quality standards or threshold values, state the proportion (%) of monitoring sites, area or volume (as appropriate) where exceedance is considered acceptable for a groundwater body to be considered in good chemical status. Quality checks: Conditional check: Report if and only if methodCriterionExtentExceedance is ‘Method 1’, ‘Method 2’ or ‘Method 3’.</xs:documentation> </xs:annotation> </xs:element> |
element GWMethodologies/impactsGWAbstractionBalance
diagram | |||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||
type | YesNoCode_Enum | ||
properties |
|
||
annotation |
|
||
source | <xs:element name="impactsGWAbstractionBalance" type="YesNoCode_Enum"> <xs:annotation> <xs:documentation>Required. Has whether the available groundwater resource is not exceeded by the long term annual average rate of abstraction been considered when assessing groundwater quantitative status? For further information regarding abstraction, refer to CIS Guidance Document No. 18 on groundwater status and trend assessment.</xs:documentation> </xs:annotation> </xs:element> |
element GWMethodologies/impactsGWAbstractionSWObjective
diagram | |||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||
type | YesNoCode_Enum | ||
properties |
|
||
annotation |
|
||
source | <xs:element name="impactsGWAbstractionSWObjective" type="YesNoCode_Enum"> <xs:annotation> <xs:documentation>Required. Has failure to achieve the WFD Environmental Objectives for associated surface water bodies resulting from anthropogenic water level alteration or change in flow conditions been considered when assessing groundwater quantitative status? For further informationregarding abstraction, refer to CIS Guidance Document No. 18 on groundwater status and trend assessment.</xs:documentation> </xs:annotation> </xs:element> |
element GWMethodologies/impactsGWAbstractionSWDiminutionStatus
diagram | |||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||
type | YesNoCode_Enum | ||
properties |
|
||
annotation |
|
||
source | <xs:element name="impactsGWAbstractionSWDiminutionStatus" type="YesNoCode_Enum"> <xs:annotation> <xs:documentation>Required. Has significant diminution in the status of surface waters resulting from anthropogenic water level alteration or change in flow conditions been considered when assessing groundwater quantitative status? For further information regarding abstraction, refer to CIS Guidance Document No. 18 on groundwater status and trend assessment.</xs:documentation> </xs:annotation> </xs:element> |
element GWMethodologies/impactsGWAbstractionDamageGWDE
diagram | |||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||
type | YesNoCode_Enum | ||
properties |
|
||
annotation |
|
||
source | <xs:element name="impactsGWAbstractionDamageGWDE" type="YesNoCode_Enum"> <xs:annotation> <xs:documentation>Required. Has significant damage to groundwater-dependent terrestrial ecosystems resulting from an anthropogenic water level alteration been considered when assessing groundwater quantitative status? For further information regarding abstraction, refer to CIS Guidance Document No. 18 on groundwater status and trend assessment.</xs:documentation> </xs:annotation> </xs:element> |
element GWMethodologies/impactsGWAbstractionSalineIntrusion
diagram | |||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||
type | YesNoCode_Enum | ||
properties |
|
||
annotation |
|
||
source | <xs:element name="impactsGWAbstractionSalineIntrusion" type="YesNoCode_Enum"> <xs:annotation> <xs:documentation>Required. Have regional saline or other intrusions resulting from anthropogenically induced sustained changes in flow direction been considered when assessing groundwater quantitative status? For further information regarding abstraction, refer to CIS Guidance Document No. 18 on groundwater status and trend assessment.</xs:documentation> </xs:annotation> </xs:element> |
element GWMethodologies/availableGroundwaterResource
diagram | |||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||
type | YesNoPartially_Union_Enum | ||
properties |
|
||
annotation |
|
||
source | <xs:element name="availableGroundwaterResource" type="YesNoPartially_Union_Enum"> <xs:annotation> <xs:documentation>Required. Indicate whether the criterion of ‘available groundwater resource’ has been applied in accordance with WFD Article 2(27), which defines ‘available groundwater resource’ as the long-term annual average rate of overall recharge of the body of groundwater less the long-term annual rate of flow required to achieve the ecological quality objectives for associated surface waters, to avoid any significant diminution in the ecological status of such waters and to avoid any significant damage to associated terrestrial ecosystems.</xs:documentation> </xs:annotation> </xs:element> |
element GWMethodologies/needsTerrestrialEcosystems
diagram | |||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||
type | YesNoNotApplicable_Union_Enum | ||
properties |
|
||
annotation |
|
||
source | <xs:element name="needsTerrestrialEcosystems" type="YesNoNotApplicable_Union_Enum"> <xs:annotation> <xs:documentation>Required. Indicate whether the needs of the terrestrial ecosystems associated to groundwater bodies have been assessed. Report ‘Not applicable’ if there are no terrestrial ecosystems associated to groundwater bodies. Quality checks: Cross-schema check: ‘Not applicable’ is a valid choice if and only if GWB/GroundWaterBody/linkTerrestrialEcosystem is ‘No’ for all groundwater bodies.</xs:documentation> </xs:annotation> </xs:element> |
element GWMethodologies/balanceRechargeAbstraction
diagram | |||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||
type | BalanceRechargeAbstraction_Enum | ||
properties |
|
||
annotation |
|
||
source | <xs:element name="balanceRechargeAbstraction" type="BalanceRechargeAbstraction_Enum"> <xs:annotation> <xs:documentation>Required. Report the approach used to assess the balance between recharge and abstraction of groundwater. - Method 1: A comparison of annual average groundwater abstraction against ‘available groundwater resource’ was done for every groundwater body - Method 2: A comparison of annual average groundwater abstraction against ‘available groundwater resource’ was done for a subset of all groundwater bodies - Method 3: Where reliable data on groundwater levels across the groundwater body is available, it can be used to identify the presence of a sustained long-term decline in water levels caused by groundwater abstraction. Where such a decline is present it indicates that the conditions for good status are not being met and the groundwater body is considered in poor status. - Not considered For further information regarding abstraction, refer to CIS Guidance Document No. 18 on groundwater status and trend assessment.</xs:documentation> </xs:annotation> </xs:element> |
element GWMethodologies/trendAssessmentPerformed
diagram | |||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||
type | YesNoCode_Enum | ||
properties |
|
||
annotation |
|
||
source | <xs:element name="trendAssessmentPerformed" type="YesNoCode_Enum"> <xs:annotation> <xs:documentation>Required. Indicate whether trend assessment in groundwater pollutants been performed.</xs:documentation> </xs:annotation> </xs:element> |
element GWMethodologies/trendAssessmentMethodology
diagram | |||||||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||||||
type | YesNoCode_Enum | ||||||
properties |
|
||||||
annotation |
|
||||||
source | <xs:element name="trendAssessmentMethodology" type="YesNoCode_Enum" minOccurs="0"> <xs:annotation> <xs:documentation>Conditional. If trend assessment in groundwater pollutants was performed, indicate whether a methodology for identifying significant and upward trends in any pollutant’s concentration has been applied. Quality checks: Conditional check: Report if and only if trendAssessmentPerformed is ‘Yes’.</xs:documentation> </xs:annotation> </xs:element> |
element GWMethodologies/timeSeries
diagram | |||||||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||||||
type | YearRangeType | ||||||
properties |
|
||||||
annotation |
|
||||||
source | <xs:element name="timeSeries" type="YearRangeType" minOccurs="0"> <xs:annotation> <xs:documentation>Conditional. If trend assessment in groundwater pollutants was performed, report the starting and finishing year for that assessment, in the format YYYY--YYYY. Quality checks: Conditional check: Report if and only if trendAssessmentPerformed is ‘Yes’.</xs:documentation> </xs:annotation> </xs:element> |
element GWMethodologies/statisticalElements
diagram | |||||||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||||||
type | StatisticalElements_Enum | ||||||
properties |
|
||||||
annotation |
|
||||||
source | <xs:element name="statisticalElements" type="StatisticalElements_Enum" minOccurs="0"> <xs:annotation> <xs:documentation>Conditional. If trend assessment in groundwater pollutants was performed, select from the enumeration list which statistical element was used. Quality checks: Conditional check: Report if and only if trendAssessmentPerformed is ‘Yes’.</xs:documentation> </xs:annotation> </xs:element> |
element GWMethodologies/additionalTrendAssessment
diagram | |||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||
type | YesNoCode_Enum | ||
properties |
|
||
annotation |
|
||
source | <xs:element name="additionalTrendAssessment" type="YesNoCode_Enum"> <xs:annotation> <xs:documentation>Required. Indicate whether additional trend assessments were applied in order to assess the impacts of existing plumes of pollution (according to Article 5(5) of the GWD).</xs:documentation> </xs:annotation> </xs:element> |
element GWMethodologies/trendReversalMethodology
diagram | |||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||
type | YesNoCode_Enum | ||
properties |
|
||
annotation |
|
||
source | <xs:element name="trendReversalMethodology" type="YesNoCode_Enum"> <xs:annotation> <xs:documentation>Required. Indicate whether a methodology for assessing trend reversal has been established. </xs:documentation> </xs:annotation> </xs:element> |
element GWMethodologies/thresholdValueElementProtectionEcosystem
diagram | |||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||
type | YesNoCode_Enum | ||
properties |
|
||
annotation |
|
||
source | <xs:element name="thresholdValueElementProtectionEcosystem" type="YesNoCode_Enum"> <xs:annotation> <xs:documentation>Required. Has the protection of aquatic ecosystems (surface waters) been considered during the establishment of the groundwater threshold values? </xs:documentation> </xs:annotation> </xs:element> |
element GWMethodologies/thresholdValueElementProtectionGWDE
diagram | |||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||
type | YesNoCode_Enum | ||
properties |
|
||
annotation |
|
||
source | <xs:element name="thresholdValueElementProtectionGWDE" type="YesNoCode_Enum"> <xs:annotation> <xs:documentation>Required. Has the protection of groundwater dependent terrestrial ecosystems (e.g. wetlands) been considered during the establishment of the groundwater threshold values? </xs:documentation> </xs:annotation> </xs:element> |
element GWMethodologies/thresholdValueElementProtectionUses
diagram | |||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||
type | YesNoCode_Enum | ||
properties |
|
||
annotation |
|
||
source | <xs:element name="thresholdValueElementProtectionUses" type="YesNoCode_Enum"> <xs:annotation> <xs:documentation>Required. Have the actual and potential legitimate uses and functions of groundwater (e.g. drinking water, irrigation, industrial use) been considered during the establishment of the groundwater threshold values? </xs:documentation> </xs:annotation> </xs:element> |
element GWMethodologies/thresholdValueElementSalineIntrusion
diagram | |||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||
type | YesNoCode_Enum | ||
properties |
|
||
annotation |
|
||
source | <xs:element name="thresholdValueElementSalineIntrusion" type="YesNoCode_Enum"> <xs:annotation> <xs:documentation>Required. Have saline or other intrusions been considered during the establishment of the groundwater threshold values? </xs:documentation> </xs:annotation> </xs:element> |
element GWMethodologies/thresholdValuesBackgroundLevels
diagram | |||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||
type | ThresholdValuesBackgroundLevels_Enum | ||
properties |
|
||
annotation |
|
||
source | <xs:element name="thresholdValuesBackgroundLevels" type="ThresholdValuesBackgroundLevels_Enum"> <xs:annotation> <xs:documentation>Required. Report whether background levels of naturally occurring substances have been considered during the establishment of threshold values. </xs:documentation> </xs:annotation> </xs:element> |
element GWMethodologies/transboundaryGWBPresent
diagram | |||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||
type | YesNoCode_Enum | ||
properties |
|
||
annotation |
|
||
source | <xs:element name="transboundaryGWBPresent" type="YesNoCode_Enum"> <xs:annotation> <xs:documentation>Required. Indicate whether there are any transboundary groundwater bodies in the RBD. Quality checks: Cross-schema check: ‘No’ should be reported if and only if GWB/GroundWaterBody/groundwaterBodyTransboundary is ‘No’ for all groundwater bodies.</xs:documentation> </xs:annotation> </xs:element> |
element GWMethodologies/transboundaryThresholdValues
diagram | |||||||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||||||
type | YesNoCode_Enum | ||||||
properties |
|
||||||
annotation |
|
||||||
source | <xs:element name="transboundaryThresholdValues" type="YesNoCode_Enum" minOccurs="0"> <xs:annotation> <xs:documentation>Conditional. If there are transboundary groundwater bodies, indicate whether the establishment of threshold values has been co-ordinated with the neighbouring countries concerned. Quality checks: Conditional check: Report if and only if transboundaryGWBPresent is ‘Yes’.</xs:documentation> </xs:annotation> </xs:element> |
element GWMethodologies/gwMethodologiesChemicalClassificationReference
diagram | |||||||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||||||
type | ReferenceType | ||||||
properties |
|
||||||
annotation |
|
||||||
source | <xs:element name="gwMethodologiesChemicalClassificationReference" type="ReferenceType" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>Required. Provide references or hyperlinks to the documents and sections where relevant information relating to methodologies for the classification of chemical status of groundwater, for upward trend assessment and for trend reversal can be found. Guidance on what should be included in this document is provided in Section 8.3.3.2.</xs:documentation> </xs:annotation> </xs:element> |
element GWMethodologies/gwMethodologiesQuantitativeClassificationReference
diagram | |||||||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||||||
type | ReferenceType | ||||||
properties |
|
||||||
annotation |
|
||||||
source | <xs:element name="gwMethodologiesQuantitativeClassificationReference" type="ReferenceType" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>Required. Provide references or hyperlinks to the documents and sections where relevant information relating to methodologies for the classification of quantitative status of groundwater can be found. Guidance on what should be included in this document is provided in Section 8.3.3.2.</xs:documentation> </xs:annotation> </xs:element> |
element GWMethodologies/gwMethodologiesTransboundaryReference
diagram | |||||||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||||||
type | ReferenceType | ||||||
properties |
|
||||||
annotation |
|
||||||
source | <xs:element name="gwMethodologiesTransboundaryReference" type="ReferenceType" minOccurs="0" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>Conditional. Provide references or hyperlinks to the documents and sections where relevant information relating to transboundary co-ordination of threshold value setting can be found. Guidance on what should be included in this document is provided in Section 8.3.3.2. Quality checks: report if 'transboundaryGWBPresent' is 'Yes'.</xs:documentation> </xs:annotation> </xs:element> |
complexType GWPressures
diagram | |||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||
children | gwPressuresNotAssessed gwSignificantPressurePointSourceTools gwSignificantPressureDiffuseSourceTools gwSignificantPressureWaterAbstractionTools gwSignificantPressureArtificialRecharge gwSignificantPressureOtherSourceTools gwSignificanceDefinition gwSignificanceLinkFailure gwPressuresReference | ||
used by |
|
||
source | <xs:complexType name="GWPressures"> <xs:sequence> <xs:element name="gwPressuresNotAssessed" type="SignificantPressureType_Enum" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>Required. Select from the enumeration list the pressure types that have not been assessed (i.e. pressure types that have not been considered because they are not relevant for groundwater, they were not deemed to be important in the RBD, no information was available, or any other reason). If all pressures have been assessed report ‘Not applicable’. The option ‘No significant pressure’ is not valid. Quality checks: Element check: the option ‘No significant pressure’ is not valid.</xs:documentation> </xs:annotation> </xs:element> <xs:element name="gwSignificantPressurePointSourceTools" type="SignificantPressureTools_Enum"> <xs:annotation> <xs:documentation>Required. Report the tools that have been used to define significant pressures from point sources. ‘Numerical tools’ includes modelling. </xs:documentation> </xs:annotation> </xs:element> <xs:element name="gwSignificantPressureDiffuseSourceTools" type="SignificantPressureTools_Enum"> <xs:annotation> <xs:documentation>Required. Report the tools that have been used to define significant pressures from diffuse sources. ‘Numerical tools’ includes modelling. </xs:documentation> </xs:annotation> </xs:element> <xs:element name="gwSignificantPressureWaterAbstractionTools" type="SignificantPressureTools_Enum"> <xs:annotation> <xs:documentation>Required. Report the tools that have been used to define significant pressures from water abstractions. ‘Numerical tools’ includes modelling.</xs:documentation> </xs:annotation> </xs:element> <xs:element name="gwSignificantPressureArtificialRecharge" type="SignificantPressureTools_Enum"> <xs:annotation> <xs:documentation>Required. Report the tools that have been used to define significant pressures from artificial recharge. ‘Numerical tools’ includes modelling.</xs:documentation> </xs:annotation> </xs:element> <xs:element name="gwSignificantPressureOtherSourceTools" type="SignificantPressureTools_Enum"> <xs:annotation> <xs:documentation>Required. Report the tools that have been used to define significant pressures from other sources. ‘Numerical tools’ includes modelling. </xs:documentation> </xs:annotation> </xs:element> <xs:element name="gwSignificanceDefinition" type="YesNoCode_Enum"> <xs:annotation> <xs:documentation>Required. Indicate whether significance has been defined in terms of thresholds (see CIS Guidance no. 18). </xs:documentation> </xs:annotation> </xs:element> <xs:element name="gwSignificanceLinkFailure" type="YesNoCode_Enum"> <xs:annotation> <xs:documentation>Required. Indicate whether the definition of significance is linked to the potential failure of good status. </xs:documentation> </xs:annotation> </xs:element> <xs:element name="gwPressuresReference" type="ReferenceType" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>Required. Provide references or hyperlinks to the documents and sections where other information relating to pressure types can be found. Guidance on what should be included in this document is provided in Section 8.4.3.2.</xs:documentation> </xs:annotation> </xs:element> </xs:sequence> </xs:complexType> |
element GWPressures/gwPressuresNotAssessed
diagram | |||||||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||||||
type | SignificantPressureType_Enum | ||||||
properties |
|
||||||
annotation |
|
||||||
source | <xs:element name="gwPressuresNotAssessed" type="SignificantPressureType_Enum" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>Required. Select from the enumeration list the pressure types that have not been assessed (i.e. pressure types that have not been considered because they are not relevant for groundwater, they were not deemed to be important in the RBD, no information was available, or any other reason). If all pressures have been assessed report ‘Not applicable’. The option ‘No significant pressure’ is not valid. Quality checks: Element check: the option ‘No significant pressure’ is not valid.</xs:documentation> </xs:annotation> </xs:element> |
element GWPressures/gwSignificantPressurePointSourceTools
diagram | |||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||
type | SignificantPressureTools_Enum | ||
properties |
|
||
annotation |
|
||
source | <xs:element name="gwSignificantPressurePointSourceTools" type="SignificantPressureTools_Enum"> <xs:annotation> <xs:documentation>Required. Report the tools that have been used to define significant pressures from point sources. ‘Numerical tools’ includes modelling. </xs:documentation> </xs:annotation> </xs:element> |
element GWPressures/gwSignificantPressureDiffuseSourceTools
diagram | |||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||
type | SignificantPressureTools_Enum | ||
properties |
|
||
annotation |
|
||
source | <xs:element name="gwSignificantPressureDiffuseSourceTools" type="SignificantPressureTools_Enum"> <xs:annotation> <xs:documentation>Required. Report the tools that have been used to define significant pressures from diffuse sources. ‘Numerical tools’ includes modelling. </xs:documentation> </xs:annotation> </xs:element> |
element GWPressures/gwSignificantPressureWaterAbstractionTools
diagram | |||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||
type | SignificantPressureTools_Enum | ||
properties |
|
||
annotation |
|
||
source | <xs:element name="gwSignificantPressureWaterAbstractionTools" type="SignificantPressureTools_Enum"> <xs:annotation> <xs:documentation>Required. Report the tools that have been used to define significant pressures from water abstractions. ‘Numerical tools’ includes modelling.</xs:documentation> </xs:annotation> </xs:element> |
element GWPressures/gwSignificantPressureArtificialRecharge
diagram | |||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||
type | SignificantPressureTools_Enum | ||
properties |
|
||
annotation |
|
||
source | <xs:element name="gwSignificantPressureArtificialRecharge" type="SignificantPressureTools_Enum"> <xs:annotation> <xs:documentation>Required. Report the tools that have been used to define significant pressures from artificial recharge. ‘Numerical tools’ includes modelling.</xs:documentation> </xs:annotation> </xs:element> |
element GWPressures/gwSignificantPressureOtherSourceTools
diagram | |||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||
type | SignificantPressureTools_Enum | ||
properties |
|
||
annotation |
|
||
source | <xs:element name="gwSignificantPressureOtherSourceTools" type="SignificantPressureTools_Enum"> <xs:annotation> <xs:documentation>Required. Report the tools that have been used to define significant pressures from other sources. ‘Numerical tools’ includes modelling. </xs:documentation> </xs:annotation> </xs:element> |
element GWPressures/gwSignificanceDefinition
diagram | |||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||
type | YesNoCode_Enum | ||
properties |
|
||
annotation |
|
||
source | <xs:element name="gwSignificanceDefinition" type="YesNoCode_Enum"> <xs:annotation> <xs:documentation>Required. Indicate whether significance has been defined in terms of thresholds (see CIS Guidance no. 18). </xs:documentation> </xs:annotation> </xs:element> |
element GWPressures/gwSignificanceLinkFailure
diagram | |||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||
type | YesNoCode_Enum | ||
properties |
|
||
annotation |
|
||
source | <xs:element name="gwSignificanceLinkFailure" type="YesNoCode_Enum"> <xs:annotation> <xs:documentation>Required. Indicate whether the definition of significance is linked to the potential failure of good status. </xs:documentation> </xs:annotation> </xs:element> |
element GWPressures/gwPressuresReference
diagram | |||||||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||||||
type | ReferenceType | ||||||
properties |
|
||||||
annotation |
|
||||||
source | <xs:element name="gwPressuresReference" type="ReferenceType" maxOccurs="unbounded"> <xs:annotation> <xs:documentation>Required. Provide references or hyperlinks to the documents and sections where other information relating to pressure types can be found. Guidance on what should be included in this document is provided in Section 8.4.3.2.</xs:documentation> </xs:annotation> </xs:element> |
complexType ThresholdValue
diagram | |||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||
children | pollutantIndicatorCode pollutantIndicatorCodeOther thresholdValueRange thresholdValueUnit thresholdDerivedFromCV cvDrinkingWaterValueRange cvDrinkingWaterValueUnit cvIrrigationValueRange cvIrrigationValueUnit cvIndustryValueRange cvIndustryValueUnit cvOtherDescription cvOtherValueRange cvOtherValueUnit thresholdValueScale startingPointTrendReversal | ||
used by |
|
||
source | <xs:complexType name="ThresholdValue"> <xs:sequence> <xs:element name="pollutantIndicatorCode" type="ChemicalSubstances_Union_Enum"> <xs:annotation> <xs:documentation>Required. Select from the enumeration list each pollutant or indicator of pollution in turn for which threshold values have been established. ‘EEA_00-00-0 – Other chemical parameter’ must be reported only when the pollutant or indicator of pollution for which a threshold value has been established is not included in the enumeration list ChemicalSubstances_Union_Enum. Quality checks: Cross-schema check: at least one entry in pollutantIndicatorCode must be reported for each pollutant or indicator reported as 'Yes' in one or more instances of GWB/GWPollutant/gwPollutantCausingRisk, except for ‘CAS_14797-55-8 – Nitrate’ and ‘EEA_34-01-5 – Pesticides (active substances in pesticides, including their relevant metabolites, degradation and reaction products) – Total’.</xs:documentation> </xs:annotation> </xs:element> <xs:element name="pollutantIndicatorCodeOther" type="String250Type" minOccurs="0"> <xs:annotation> <xs:documentation>Conditional. If pollutantIndicatorCode is ‘EEA_00-00-0 Other chemical parameter’ please indicate in this field the CAS number (if relevant) and the name of the pollutant or indicator. Quality check: Conditional check: report if and only if pollutantIndicatorCode is ‘EEA_00-00-0 Other chemical parameter’. </xs:documentation> </xs:annotation> </xs:element> <xs:element name="thresholdValueRange" type="String25Type"> <xs:annotation> <xs:documentation>Required. Report the threshold value or range of threshold values established for the selected pollutant or indicator of pollution. The threshold values established for nitrates and pesticides need only be reported if they are more stringent than the groundwater quality standards identified in GWD Annex I. </xs:documentation> </xs:annotation> </xs:element> <xs:element name="thresholdValueUnit" type="UnitOfMeasure_Enum"> <xs:annotation> <xs:documentation>Required. Report the unit of measurement of the threshold value or range of threshold values. </xs:documentation> </xs:annotation> </xs:element> <xs:element name="thresholdDerivedFromCV" type="YesNoCode_Enum"> <xs:annotation> <xs:documentation>Required. Indicate whether the threshold values were derived from criteria values. Quality checks: Within-schema check: If thresholdDerivedFromCV is ‘Yes’, at least one of the elements cvDrinkingWaterValueRange, cvIrrigationValueRange, cvIndustryValueRange or cvOtherDescription needs to be reported. If thresholdDerivedFromCV is ‘No’, none of the elements cvDrinkingWaterValueRange, cvIrrigationValueRange, cvIndustryValueRange or cvOtherDescription should be reported.</xs:documentation> </xs:annotation> </xs:element> <xs:element name="cvDrinkingWaterValueRange" type="String25Type" minOccurs="0"> <xs:annotation> <xs:documentation>Optional. Report the criteria value or range of criteria values established for the selected pollutant or indicator of pollution for drinking water. If your report that the threshold values were derived from criteria values (thresholdDerivedFromCV is ‘Yes’) at least one of the elements cvDrinkingWaterValueRange, cvIrrigationValueRange, cvIndustry or cvOtherDescription needs to be reported, together with cvOtherValueRange and the corresponding element on units of measurement.</xs:documentation> </xs:annotation> </xs:element> <xs:element name="cvDrinkingWaterValueUnit" type="UnitOfMeasure_Enum" minOccurs="0"> <xs:annotation> <xs:documentation>Conditional. If cvDrinkingWaterValueRange is reported, report the unit of measurement of the criteria value or range of criteria values. Quality checks: Conditional check: Report if and only if cvDrinkingWaterValueRange is reported.</xs:documentation> </xs:annotation> </xs:element> <xs:element name="cvIrrigationValueRange" type="String25Type" minOccurs="0"> <xs:annotation> <xs:documentation>Optional. Report the criteria value or range of criteria values established for the selected pollutant or indicator of pollution for irrigation. If your report that the threshold values were derived from criteria values (thresholdDerivedFromCV is ‘Yes’) at least one of the elements cvDrinkingWaterValueRange, cvIrrigationValueRange, cvIndustry or cvOtherDescription needs to be reported, together with cvOtherValueRange and the corresponding element on units of measurement.</xs:documentation> </xs:annotation> </xs:element> <xs:element name="cvIrrigationValueUnit" type="UnitOfMeasure_Enum" minOccurs="0"> <xs:annotation> <xs:documentation>Conditional. If cvIrrigationValueRange is reported, report the unit of measurement of the criteria value or range of criteria values. Quality checks: Conditional check: Report if and only if cvIrrigationValueRange is reported.</xs:documentation> </xs:annotation> </xs:element> <xs:element name="cvIndustryValueRange" type="String25Type" minOccurs="0"> <xs:annotation> <xs:documentation>Optional. Report the criteria value or range of criteria values established for the selected pollutant or indicator of pollution for industry. If your report that the threshold values were derived from criteria values (thresholdDerivedFromCV is ‘Yes’) at least one of the elements cvDrinkingWaterValueRange, cvIrrigationValueRange, cvIndustry or cvOtherDescription needs to be reported, together with cvOtherValueRange and the corresponding element on units of measurement.</xs:documentation> </xs:annotation> </xs:element> <xs:element name="cvIndustryValueUnit" type="UnitOfMeasure_Enum" minOccurs="0"> <xs:annotation> <xs:documentation>Conditional. If cvIndustryValueRange is reported, report the unit of measurement of the criteria value or range of criteria values. Quality checks: Conditional check: Report if and only if cvIndustryValueRange is reported.</xs:documentation> </xs:annotation> </xs:element> <xs:element name="cvOtherDescription" type="String100Type" minOccurs="0"> <xs:annotation> <xs:documentation>Optional. If threshold values were based on criteria values for uses other than drinking water, irrigation and industry, describe shortly the use being reported. If your report that the threshold values were derived from criteria values (thresholdDerivedFromCV is ‘Yes’) at least one of the elements cvDrinkingWaterValueRange, cvIrrigationValueRange, cvIndustry or cvOtherDescription needs to be reported, together with cvOtherValueRange and the corresponding element on units of measurement.</xs:documentation> </xs:annotation> </xs:element> <xs:element name="cvOtherValueRange" type="String25Type" minOccurs="0"> <xs:annotation> <xs:documentation>Conditional. If cvOtherDescription is reported, report the criteria value or range of criteria values established for the selected pollutant or indicator of pollution for the use concerned. Quality checks: Conditional check: Report if and only if cvOtherDescription is reported.</xs:documentation> </xs:annotation> </xs:element> <xs:element name="cvOtherValueUnit" type="UnitOfMeasure_Enum"> <xs:annotation> <xs:documentation>Required. Report the level at which the threshold value is established. </xs:documentation> </xs:annotation> </xs:element> <xs:element name="thresholdValueScale" type="GeographicalScale_Enum"> <xs:annotation> <xs:documentation>Required. Report the level at which the threshold value is established. </xs:documentation> </xs:annotation> </xs:element> <xs:element name="startingPointTrendReversal" type="String25Type"> <xs:annotation> <xs:documentation>Required. Report the percentage starting point for trend reversal. The default value is ‘75’, i.e. 75 % of the threshold value. If different starting points for trend reversal are applied for the same pollutant or indicator at groundwater body level within the RBD, indicate the range of the starting points applied.</xs:documentation> </xs:annotation> </xs:element> </xs:sequence> </xs:complexType> |
element ThresholdValue/pollutantIndicatorCode
diagram | |||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||
type | ChemicalSubstances_Union_Enum | ||
properties |
|
||
annotation |
|
||
source | <xs:element name="pollutantIndicatorCode" type="ChemicalSubstances_Union_Enum"> <xs:annotation> <xs:documentation>Required. Select from the enumeration list each pollutant or indicator of pollution in turn for which threshold values have been established. ‘EEA_00-00-0 – Other chemical parameter’ must be reported only when the pollutant or indicator of pollution for which a threshold value has been established is not included in the enumeration list ChemicalSubstances_Union_Enum. Quality checks: Cross-schema check: at least one entry in pollutantIndicatorCode must be reported for each pollutant or indicator reported as 'Yes' in one or more instances of GWB/GWPollutant/gwPollutantCausingRisk, except for ‘CAS_14797-55-8 – Nitrate’ and ‘EEA_34-01-5 – Pesticides (active substances in pesticides, including their relevant metabolites, degradation and reaction products) – Total’.</xs:documentation> </xs:annotation> </xs:element> |
element ThresholdValue/pollutantIndicatorCodeOther
diagram | |||||||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||||||
type | String250Type | ||||||
properties |
|
||||||
annotation |
|
||||||
source | <xs:element name="pollutantIndicatorCodeOther" type="String250Type" minOccurs="0"> <xs:annotation> <xs:documentation>Conditional. If pollutantIndicatorCode is ‘EEA_00-00-0 Other chemical parameter’ please indicate in this field the CAS number (if relevant) and the name of the pollutant or indicator. Quality check: Conditional check: report if and only if pollutantIndicatorCode is ‘EEA_00-00-0 Other chemical parameter’. </xs:documentation> </xs:annotation> </xs:element> |
element ThresholdValue/thresholdValueRange
diagram | |||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||
type | String25Type | ||
properties |
|
||
annotation |
|
||
source | <xs:element name="thresholdValueRange" type="String25Type"> <xs:annotation> <xs:documentation>Required. Report the threshold value or range of threshold values established for the selected pollutant or indicator of pollution. The threshold values established for nitrates and pesticides need only be reported if they are more stringent than the groundwater quality standards identified in GWD Annex I. </xs:documentation> </xs:annotation> </xs:element> |
element ThresholdValue/thresholdValueUnit
diagram | |||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||
type | UnitOfMeasure_Enum | ||
properties |
|
||
annotation |
|
||
source | <xs:element name="thresholdValueUnit" type="UnitOfMeasure_Enum"> <xs:annotation> <xs:documentation>Required. Report the unit of measurement of the threshold value or range of threshold values. </xs:documentation> </xs:annotation> </xs:element> |
element ThresholdValue/thresholdDerivedFromCV
diagram | |||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||
type | YesNoCode_Enum | ||
properties |
|
||
annotation |
|
||
source | <xs:element name="thresholdDerivedFromCV" type="YesNoCode_Enum"> <xs:annotation> <xs:documentation>Required. Indicate whether the threshold values were derived from criteria values. Quality checks: Within-schema check: If thresholdDerivedFromCV is ‘Yes’, at least one of the elements cvDrinkingWaterValueRange, cvIrrigationValueRange, cvIndustryValueRange or cvOtherDescription needs to be reported. If thresholdDerivedFromCV is ‘No’, none of the elements cvDrinkingWaterValueRange, cvIrrigationValueRange, cvIndustryValueRange or cvOtherDescription should be reported.</xs:documentation> </xs:annotation> </xs:element> |
element ThresholdValue/cvDrinkingWaterValueRange
diagram | |||||||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||||||
type | String25Type | ||||||
properties |
|
||||||
annotation |
|
||||||
source | <xs:element name="cvDrinkingWaterValueRange" type="String25Type" minOccurs="0"> <xs:annotation> <xs:documentation>Optional. Report the criteria value or range of criteria values established for the selected pollutant or indicator of pollution for drinking water. If your report that the threshold values were derived from criteria values (thresholdDerivedFromCV is ‘Yes’) at least one of the elements cvDrinkingWaterValueRange, cvIrrigationValueRange, cvIndustry or cvOtherDescription needs to be reported, together with cvOtherValueRange and the corresponding element on units of measurement.</xs:documentation> </xs:annotation> </xs:element> |
element ThresholdValue/cvDrinkingWaterValueUnit
diagram | |||||||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||||||
type | UnitOfMeasure_Enum | ||||||
properties |
|
||||||
annotation |
|
||||||
source | <xs:element name="cvDrinkingWaterValueUnit" type="UnitOfMeasure_Enum" minOccurs="0"> <xs:annotation> <xs:documentation>Conditional. If cvDrinkingWaterValueRange is reported, report the unit of measurement of the criteria value or range of criteria values. Quality checks: Conditional check: Report if and only if cvDrinkingWaterValueRange is reported.</xs:documentation> </xs:annotation> </xs:element> |
element ThresholdValue/cvIrrigationValueRange
diagram | |||||||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||||||
type | String25Type | ||||||
properties |
|
||||||
annotation |
|
||||||
source | <xs:element name="cvIrrigationValueRange" type="String25Type" minOccurs="0"> <xs:annotation> <xs:documentation>Optional. Report the criteria value or range of criteria values established for the selected pollutant or indicator of pollution for irrigation. If your report that the threshold values were derived from criteria values (thresholdDerivedFromCV is ‘Yes’) at least one of the elements cvDrinkingWaterValueRange, cvIrrigationValueRange, cvIndustry or cvOtherDescription needs to be reported, together with cvOtherValueRange and the corresponding element on units of measurement.</xs:documentation> </xs:annotation> </xs:element> |
element ThresholdValue/cvIrrigationValueUnit
diagram | |||||||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||||||
type | UnitOfMeasure_Enum | ||||||
properties |
|
||||||
annotation |
|
||||||
source | <xs:element name="cvIrrigationValueUnit" type="UnitOfMeasure_Enum" minOccurs="0"> <xs:annotation> <xs:documentation>Conditional. If cvIrrigationValueRange is reported, report the unit of measurement of the criteria value or range of criteria values. Quality checks: Conditional check: Report if and only if cvIrrigationValueRange is reported.</xs:documentation> </xs:annotation> </xs:element> |
element ThresholdValue/cvIndustryValueRange
diagram | |||||||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||||||
type | String25Type | ||||||
properties |
|
||||||
annotation |
|
||||||
source | <xs:element name="cvIndustryValueRange" type="String25Type" minOccurs="0"> <xs:annotation> <xs:documentation>Optional. Report the criteria value or range of criteria values established for the selected pollutant or indicator of pollution for industry. If your report that the threshold values were derived from criteria values (thresholdDerivedFromCV is ‘Yes’) at least one of the elements cvDrinkingWaterValueRange, cvIrrigationValueRange, cvIndustry or cvOtherDescription needs to be reported, together with cvOtherValueRange and the corresponding element on units of measurement.</xs:documentation> </xs:annotation> </xs:element> |
element ThresholdValue/cvIndustryValueUnit
diagram | |||||||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||||||
type | UnitOfMeasure_Enum | ||||||
properties |
|
||||||
annotation |
|
||||||
source | <xs:element name="cvIndustryValueUnit" type="UnitOfMeasure_Enum" minOccurs="0"> <xs:annotation> <xs:documentation>Conditional. If cvIndustryValueRange is reported, report the unit of measurement of the criteria value or range of criteria values. Quality checks: Conditional check: Report if and only if cvIndustryValueRange is reported.</xs:documentation> </xs:annotation> </xs:element> |
element ThresholdValue/cvOtherDescription
diagram | |||||||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||||||
type | String100Type | ||||||
properties |
|
||||||
annotation |
|
||||||
source | <xs:element name="cvOtherDescription" type="String100Type" minOccurs="0"> <xs:annotation> <xs:documentation>Optional. If threshold values were based on criteria values for uses other than drinking water, irrigation and industry, describe shortly the use being reported. If your report that the threshold values were derived from criteria values (thresholdDerivedFromCV is ‘Yes’) at least one of the elements cvDrinkingWaterValueRange, cvIrrigationValueRange, cvIndustry or cvOtherDescription needs to be reported, together with cvOtherValueRange and the corresponding element on units of measurement.</xs:documentation> </xs:annotation> </xs:element> |
element ThresholdValue/cvOtherValueRange
diagram | |||||||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||||||
type | String25Type | ||||||
properties |
|
||||||
annotation |
|
||||||
source | <xs:element name="cvOtherValueRange" type="String25Type" minOccurs="0"> <xs:annotation> <xs:documentation>Conditional. If cvOtherDescription is reported, report the criteria value or range of criteria values established for the selected pollutant or indicator of pollution for the use concerned. Quality checks: Conditional check: Report if and only if cvOtherDescription is reported.</xs:documentation> </xs:annotation> </xs:element> |
element ThresholdValue/cvOtherValueUnit
diagram | |||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||
type | UnitOfMeasure_Enum | ||
properties |
|
||
annotation |
|
||
source | <xs:element name="cvOtherValueUnit" type="UnitOfMeasure_Enum"> <xs:annotation> <xs:documentation>Required. Report the level at which the threshold value is established. </xs:documentation> </xs:annotation> </xs:element> |
element ThresholdValue/thresholdValueScale
diagram | |||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||
type | GeographicalScale_Enum | ||
properties |
|
||
annotation |
|
||
source | <xs:element name="thresholdValueScale" type="GeographicalScale_Enum"> <xs:annotation> <xs:documentation>Required. Report the level at which the threshold value is established. </xs:documentation> </xs:annotation> </xs:element> |
element ThresholdValue/startingPointTrendReversal
diagram | |||
namespace | http://dd.eionet.europa.eu/schemas/WFD2022 | ||
type | String25Type | ||
properties |
|
||
annotation |
|
||
source | <xs:element name="startingPointTrendReversal" type="String25Type"> <xs:annotation> <xs:documentation>Required. Report the percentage starting point for trend reversal. The default value is ‘75’, i.e. 75 % of the threshold value. If different starting points for trend reversal are applied for the same pollutant or indicator at groundwater body level within the RBD, indicate the range of the starting points applied.</xs:documentation> </xs:annotation> </xs:element> |
simpleType FeatureUniqueEUCodeType
namespace | http://dd.eionet.europa.eu/schemas/WFD2022/wfdcommon | ||||||||||||
type | restriction of xs:string | ||||||||||||
facets |
|
||||||||||||
annotation |
|
||||||||||||
source | <xs:simpleType name="FeatureUniqueEUCodeType"> <xs:annotation> <xs:documentation>2020 Type for EU code, allows up to 42 characters (unique code within MS prefixed with country ISO 2 character code</xs:documentation> </xs:annotation> <xs:restriction base="xs:string"> <xs:minLength value="3"/> <xs:maxLength value="42"/> <xs:pattern value="[A-Z]{2}[0-9A-Z]{1}([0-9A-Z_\-]{0,38}[0-9A-Z]{1}){0,1}"/> </xs:restriction> </xs:simpleType> |
simpleType NonNegativeDecimalType
namespace | http://dd.eionet.europa.eu/schemas/WFD2022/wfdcommon | ||||||
type | restriction of xs:decimal | ||||||
facets |
|
||||||
annotation |
|
||||||
source | <xs:simpleType name="NonNegativeDecimalType"> <xs:annotation> <xs:documentation>Non negative decimal</xs:documentation> </xs:annotation> <xs:restriction base="xs:decimal"> <xs:minInclusive value="0"/> </xs:restriction> </xs:simpleType> |
simpleType PositiveDecimalType
namespace | http://dd.eionet.europa.eu/schemas/WFD2022/wfdcommon | ||||||
type | restriction of xs:decimal | ||||||
facets |
|
||||||
annotation |
|
||||||
source | <xs:simpleType name="PositiveDecimalType"> <xs:annotation> <xs:documentation>Positive decimal</xs:documentation> </xs:annotation> <xs:restriction base="xs:decimal"> <xs:minExclusive value="0"/> </xs:restriction> </xs:simpleType> |
simpleType String1000Type
namespace | http://dd.eionet.europa.eu/schemas/WFD2022/wfdcommon | |||||||||
type | restriction of xs:string | |||||||||
facets |
|
|||||||||
annotation |
|
|||||||||
source | <xs:simpleType name="String1000Type"> <xs:annotation> <xs:documentation>2020 String of up to 1000 characters</xs:documentation> </xs:annotation> <xs:restriction base="xs:string"> <xs:minLength value="1"/> <xs:maxLength value="1000"/> </xs:restriction> </xs:simpleType> |
simpleType String100Type
namespace | http://dd.eionet.europa.eu/schemas/WFD2022/wfdcommon | |||||||||
type | restriction of xs:string | |||||||||
facets |
|
|||||||||
annotation |
|
|||||||||
source | <xs:simpleType name="String100Type"> <xs:annotation> <xs:documentation>2020 String of up to 100 characters</xs:documentation> </xs:annotation> <xs:restriction base="xs:string"> <xs:minLength value="1"/> <xs:maxLength value="100"/> </xs:restriction> </xs:simpleType> |
simpleType String10Type
namespace | http://dd.eionet.europa.eu/schemas/WFD2022/wfdcommon | |||||||||
type | restriction of xs:string | |||||||||
facets |
|
|||||||||
annotation |
|
|||||||||
source | <xs:simpleType name="String10Type"> <xs:annotation> <xs:documentation>2020 String of up to 10 characters</xs:documentation> </xs:annotation> <xs:restriction base="xs:string"> <xs:minLength value="1"/> <xs:maxLength value="10"/> </xs:restriction> </xs:simpleType> |
simpleType String20Type
namespace | http://dd.eionet.europa.eu/schemas/WFD2022/wfdcommon | |||||||||
type | restriction of xs:string | |||||||||
facets |
|
|||||||||
annotation |
|
|||||||||
source | <xs:simpleType name="String20Type"> <xs:annotation> <xs:documentation>2020 String of up to 20 characters</xs:documentation> </xs:annotation> <xs:restriction base="xs:string"> <xs:minLength value="1"/> <xs:maxLength value="20"/> </xs:restriction> </xs:simpleType> |
simpleType String2500Type
namespace | http://dd.eionet.europa.eu/schemas/WFD2022/wfdcommon | |||||||||
type | restriction of xs:string | |||||||||
facets |
|
|||||||||
annotation |
|
|||||||||
source | <xs:simpleType name="String2500Type"> <xs:annotation> <xs:documentation>2020 String of up to 2500 characters</xs:documentation> </xs:annotation> <xs:restriction base="xs:string"> <xs:minLength value="1"/> <xs:maxLength value="2500"/> </xs:restriction> </xs:simpleType> |
simpleType String250Type
namespace | http://dd.eionet.europa.eu/schemas/WFD2022/wfdcommon | |||||||||
type | restriction of xs:string | |||||||||
facets |
|
|||||||||
annotation |
|
|||||||||
source | <xs:simpleType name="String250Type"> <xs:annotation> <xs:documentation>2020 String of up to 250 characters</xs:documentation> </xs:annotation> <xs:restriction base="xs:string"> <xs:minLength value="1"/> <xs:maxLength value="250"/> </xs:restriction> </xs:simpleType> |
simpleType String254Type
namespace | http://dd.eionet.europa.eu/schemas/WFD2022/wfdcommon | ||||||||||||
type | restriction of xs:string | ||||||||||||
facets |
|
||||||||||||
annotation |
|
||||||||||||
source | <xs:simpleType name="String254Type"> <xs:annotation> <xs:documentation>2020 String of up to 254 characters</xs:documentation> </xs:annotation> <xs:restriction base="xs:string"> <xs:minLength value="1"/> <xs:maxLength value="254"/> <xs:pattern value="(\p{L}|[0-9]){1}.{0,253}"/> </xs:restriction> </xs:simpleType> |
simpleType String25Type
namespace | http://dd.eionet.europa.eu/schemas/WFD2022/wfdcommon | |||||||||
type | restriction of xs:string | |||||||||
facets |
|
|||||||||
annotation |
|
|||||||||
source | <xs:simpleType name="String25Type"> <xs:annotation> <xs:documentation>2020 String of up to 25 characters</xs:documentation> </xs:annotation> <xs:restriction base="xs:string"> <xs:minLength value="1"/> <xs:maxLength value="25"/> </xs:restriction> </xs:simpleType> |
simpleType String4000Type
namespace | http://dd.eionet.europa.eu/schemas/WFD2022/wfdcommon | |||||||||
type | restriction of xs:string | |||||||||
facets |
|
|||||||||
annotation |
|
|||||||||
source | <xs:simpleType name="String4000Type"> <xs:annotation> <xs:documentation>2020 String of up to 4000 characters</xs:documentation> </xs:annotation> <xs:restriction base="xs:string"> <xs:minLength value="1"/> <xs:maxLength value="4000"/> </xs:restriction> </xs:simpleType> |
simpleType String50Type
namespace | http://dd.eionet.europa.eu/schemas/WFD2022/wfdcommon | |||||||||
type | restriction of xs:string | |||||||||
facets |
|
|||||||||
annotation |
|
|||||||||
source | <xs:simpleType name="String50Type"> <xs:annotation> <xs:documentation>2020 String of up to 50 characters</xs:documentation> </xs:annotation> <xs:restriction base="xs:string"> <xs:minLength value="1"/> <xs:maxLength value="50"/> </xs:restriction> </xs:simpleType> |
simpleType URLType
namespace | http://dd.eionet.europa.eu/schemas/WFD2022/wfdcommon | ||||||||||||
type | restriction of xs:string | ||||||||||||
facets |
|
||||||||||||
annotation |
|
||||||||||||
source | <xs:simpleType name="URLType"> <xs:annotation> <xs:documentation>URL string of up to 250 characters</xs:documentation> </xs:annotation> <xs:restriction base="xs:string"> <xs:minLength value="1"/> <xs:maxLength value="250"/> <xs:pattern value="https?://.*"/> </xs:restriction> </xs:simpleType> |
simpleType WiseDate
namespace | http://dd.eionet.europa.eu/schemas/WFD2022/wfdcommon | ||||||
type | restriction of xs:date | ||||||
facets |
|
||||||
source | <xs:simpleType name="WiseDate"> <xs:restriction base="xs:date"> <xs:pattern value="\d{4}-\d{2}-\d{2}"/> </xs:restriction> </xs:simpleType> |
simpleType WiseDateTime
namespace | http://dd.eionet.europa.eu/schemas/WFD2022/wfdcommon | ||||||
type | restriction of xs:dateTime | ||||||
facets |
|
||||||
source | <xs:simpleType name="WiseDateTime"> <xs:restriction base="xs:dateTime"> <xs:pattern value="\d{4}-\d{2}-\d{2}T\d{2}:\d{2}:\d{2}"/> </xs:restriction> </xs:simpleType> |
simpleType WiseDateTimeType
namespace | http://dd.eionet.europa.eu/schemas/WFD2022/wfdcommon | ||
type | union of (WiseDate, WiseDateTime, WiseYear, WiseYearMonth) | ||
annotation |
|
||
source | <xs:simpleType name="WiseDateTimeType"> <xs:annotation> <xs:documentation>Dates must be reported using the ISO 8601 extended format: YYYY-MM-DD, for days; YYYY-MM, for months; YYYY, for years. (If necessary, or convenient, time values can be reported. The ISO 8601 extended format for UTC time should be used.)</xs:documentation> </xs:annotation> <xs:union memberTypes="WiseDate WiseDateTime WiseYear WiseYearMonth"/> </xs:simpleType> |
simpleType WiseLanguageCode_Enum
namespace | http://dd.eionet.europa.eu/schemas/WFD2022/wfdcommon | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
type | restriction of xs:string | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
facets |
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
source | <xs:simpleType name="WiseLanguageCode_Enum"> <xs:restriction base="xs:string"> <xs:enumeration value="alb"/> <xs:enumeration value="arm"/> <xs:enumeration value="baq"/> <xs:enumeration value="bel"/> <xs:enumeration value="bul"/> <xs:enumeration value="cat"/> <xs:enumeration value="cze"/> <xs:enumeration value="dan"/> <xs:enumeration value="dut"/> <xs:enumeration value="eng"/> <xs:enumeration value="est"/> <xs:enumeration value="fao"/> <xs:enumeration value="fin"/> <xs:enumeration value="fre"/> <xs:enumeration value="geo"/> <xs:enumeration value="ger"/> <xs:enumeration value="gle"/> <xs:enumeration value="glg"/> <xs:enumeration value="gre"/> <xs:enumeration value="hrv"/> <xs:enumeration value="hun"/> <xs:enumeration value="ice"/> <xs:enumeration value="ita"/> <xs:enumeration value="lav"/> <xs:enumeration value="lit"/> <xs:enumeration value="ltz"/> <xs:enumeration value="mac"/> <xs:enumeration value="mis"/> <xs:enumeration value="mlt"/> <xs:enumeration value="nor"/> <xs:enumeration value="pol"/> <xs:enumeration value="por"/> <xs:enumeration value="roh"/> <xs:enumeration value="rum"/> <xs:enumeration value="rus"/> <xs:enumeration value="slo"/> <xs:enumeration value="slv"/> <xs:enumeration value="spa"/> <xs:enumeration value="srp"/> <xs:enumeration value="swe"/> <xs:enumeration value="tur"/> <xs:enumeration value="ukr"/> </xs:restriction> </xs:simpleType> |
simpleType WiseYear
namespace | http://dd.eionet.europa.eu/schemas/WFD2022/wfdcommon | ||||||
type | restriction of xs:gYear | ||||||
facets |
|
||||||
source | <xs:simpleType name="WiseYear"> <xs:restriction base="xs:gYear"> <xs:pattern value="\d{4}"/> </xs:restriction> </xs:simpleType> |
simpleType WiseYearMonth
namespace | http://dd.eionet.europa.eu/schemas/WFD2022/wfdcommon | ||||||
type | restriction of xs:gYearMonth | ||||||
facets |
|
||||||
source | <xs:simpleType name="WiseYearMonth"> <xs:restriction base="xs:gYearMonth"> <xs:pattern value="\d{4}-\d{2}"/> </xs:restriction> </xs:simpleType> |
XML Schema documentation generated by XMLSpy Schema Editor http://www.altova.com/xmlspy